Our Products/ RuggedMAX™/ WiN PS 3S-ODU
Product Information
The WiNPS 3S-ODU is a member of the RuggedMAX™ family, a line of mobile WiMAX broadband wireless access systems based on the 802.16e mobile WiMAX standard. The WiNPS 3S-ODU serves as the power and data distribution for the WiN7000 multi sector base station. The unique design charges the battery bank and supplies backup power during AC power failure.
A high performance, hot-swap system controller measures, monitors and controls all parameters such as voltages, current, power, battery, and temperature. Comprehensive remote control and monitoring of the system can be done using a dedicated graphical user interface. The WiNPS comes with automatic and pre-programmed battery testing and equalize charging modes for easy, care-free maintenance.
The WiNPS 3S-ODU is supplied with a proprietary cable with the ability to connect the WiNPS 3S-ODU power system to multiple compact base stations. The WiNPS 3S-ODU is fully managed by WiNMS. WiNMS is a comprehensive carrier-class network management system for RuggedMAX™ products-based networks.
Product Features & Specs
- Outdoor or secure indoor installations
- Power Supply Redundancy supporting 2x650W power supply with load sharing capabilities
- Supports up to 3 sectors of compact base stations (2x650W) using the proprietary WiN-Cable.
- Universal input voltage
- Built-in battery protection with Electronic Low Voltage Disconnect device (ELVD)
- High performance hot swap system
- System controller that measure, monitor and control voltages, currents, power, battery and temperature.
- Scalable battery support including battery current limit and monitoring
- Alert features and power supply alarms
- Dedicated thermal-magnetic circuit breaker protects the battery and load terminals
- Wall, pedestal, rack or pole mounting options
Interfaces:
- AC Input
- Universal AC input 110/220VAC
- DC+ETH Output
- 3 ports, Per Port:
- 48VDC, 215W
- ETH, CAT5, 100m
- Local Management
- ETH, (internal only-after opening the door)
AC Input:
- Voltage
- 90-264Vac, single phase
- Frequency
- 47-63Hz
- Inrush Current
- ≤ full load steady state current of the rectifier within rated limits
- Efficiency
- 90% typical at 120Vac, full load rated power (650W)
- AC input current
- 3.0 to 3.5A (nominal Vac)
- 4.9A maximum @150Vac
- Power Factor
- >0.99 at nominal conditions and 50-100% load;
- >0.98 at nominal conditions and 30-50% load
- Input Protection
- A 250Vac FAST ACTION Circuit Breaker
Mechanical:
- Size [WxHxD]
- 55x52x52 cm
- Weight
- 35 Kg
- Input AC Connector
- Terminal block
- DC Output Connector
- Terminal block
- Network Connector
- RJ45
Management:
- Management
- Internet: Web-based management
- Interfaces: Telnet, SNMP, Web, Remote
- SNMP
- SNMP Client MIBs:
- MIB II, Private MIB
- Remote Configuration
- Auto Configuration: DHCP
- SW Download: via TFTP
- PS Fault Alarms
- Power Supply
- DC output
- Battery low voltage
- Additional Alarms
- TBD
Environmental:
- Temperature
- Operating: -40°C to +46°C + Solar radiation
- Storage: -40°C to +85°C
- Cold Start Temperature
- -40°C
- Temperature Coefficient
- ≤100ppm/°C over the operating range
- Humidity
- Maximum 5% to 95% RH
non-condensation - Altitude
- Operating -1640 to 9840 ft
- Non-operating 40,000 ft
- Vibration
- Zone 4 requirements
- Cooling
- two cooling fans
- Water Tightness
- NEMA Type 3R
DC Output:
- Power
- 42-58VDC, 2 x 650W (3 Sectors BST)
- Load
- Max: 2x12A
- Peak: 2x13.5A
- Line Regulation
- Static <±0.1%
- Dynamic <±1% for any change within rated limits
- Load Regulation
- Static <±0.5%
- Dynamic <±1% for 40 to 90% load step 2ms recovery time
- Turn On Delay
- 5 sec. Maximum
(excluding soft start) - Hold-up Time
- 10msec minimum at 110Vac and full load
- Turn-On Rise Time
- 105 to 120% of IMax, constant current limit, automatic recovery, when cause of overload or short is removed
- Over-current Protection
- 105 to 120% of IMax, constant current limit, automatic recovery, when cause of overload or short is removed
- Over-voltage Protection
- Shut down at 120 ÷ 125% of nominal output, AC input must be recycled to restart
- Temperature Protection
- Shutdown due to excessive ambient temperature at over heating or malfunctions of cooling fans. The sense point is at 90°C for the internal heat signal, unit recovers automatically typical hysterisis 20°C
- Current Share
- The unit works with similar units to form a redundant power module configuration. A single wire load share mechanism is used between similar units
- Hot Swap
- Internal O-Ring diode (FET)
Battery Compatibility
- Voltage
- 12V (one string 48VDC)
- Number
- 4
- Type
- Gelled Electrolyte
- Capacity
- 44Ah (optional 33Ah, 26Ah)
Safety & EMC Regulations:
- EMC
- FCC class B, EN55022 CLASS B
- Safety
- CSA C22.2 No 60950-1-03
- UL 60950-1
- IEC/EN 60950-1
- CE – MARK
- EN61000-3-2
- HARMONICS
- EN61000-3-3
- Voltage Fluctuation
- EN6000-4-2
- ESD +8KV AIR +4KV CONTACT DISCHARGE, performance criteria B
- EN61000-4-3
- Radiated Immunity: 80-1000Mhz 3V/m, AM 80% (1KHz), criteria A
- EN61000-4-4
- Fast Transient: 1KV for AC power port, 0.5KV for DC power I/O and signals Port, performance criteria B
- Capacity
- Surge: 2KV common mode and 1KV differential mode
- EN61000-4-6
- 3VRMS, 80% A.M. BY 1kHz
- EN61000-4-11
- Voltage Dips and interruption: 30% reduction for 10mSec –Criteria B, 60% For 100mSec. Criteria C, 95% reduction for 5000mSec Criteria C
- Dielectric Withstand
- Input to case: 1500VAC.
- Input to output: 3000VAC
- Output to case: 2100VDC
- Leakage Current:
- <3.5mA @ 265Vac 60Hz
- MTBF
- 200,000 hours minimum per BELCOR 332, issue 6 specification @ 30°C